MixRite Water-Driven Dosing Pump
-
WMR049 MixRite Water-Driven Dosing Pump - 0.03% to 0.9% (3333:1 - 500:1 ) Dosage Rate - 0.5 to 14 GPM - 3/4-Inch MPT -
WMR050 MixRite Water-Driven Dosing Pump - 0.3% to 2% (333:1 - 50:1) Dosage Rate- 0.5 to 14 GPM - 3/4-Inch MPT -
WMR060 MixRite Water-Driven Dosing Pump - 0.1% to 0.9% (1000:1 - 111:1) Dosage Rate - 0.5 to 14 GPM - 3/4-Inch MPT -
WMR007 MixRite TF5 Water-Driven Dosing Pump - 0.2% to 2% (500:1 - 50:1) Dosage Rate - Manual On/Off & Viton Seals - 1 to 22 GPM- 1-Inch MPT -
WMR008 MixRite TF5 Water-Driven Dosing Pump - 0.2% to 2% (500:1 - 50:1) Dosage Rate - Manual On/Off - 1 to 22 GPM - 1-Inch MPT -
WMR020 MixRite TF10 Water-Driven Dosing Pump - 0.2% to 2% (500:1 - 50:1) Dosage Rate - 2 to 45 GPM - 1-1/2-Inch MPT -
WMR030 MixRite TF10 Water-Driven Dosing Pump - 0.1% to 1% (1000:1 - 100:1) Dosage Rate - Chlorine & PPA Compatible - 2 to 45 GPM- 1-1/2-Inch MPT
Details
MixRite Water Driven Injectors are water powered proportioning pumps that need no electricity and accurately dispenses at different water pressure and water flows. Ideal for in-line injection of fertilizers and additives for crop production or simply adjusting pH. Mixrite products are manufactured in an ISO certified facility and are ISO 9001 2008 certified.
Available in several models with a wide variety of injection rates, and different materials to withstand many types of aggressive acids, alkaline, and solvents.
The 500 series is available as a CW model with seals and components for mildly aggressive additives, 1400 models for corrosive material, acid, alkaline, solvent, and a PVDF model for the most aggressive additives.
We understand that everyone is not an expert in irrigation. If you need assistance understanding our Mixrite dosing pumps and determining which product is correct for your installation please give us a call. Our MORR technical sales representatives are available for product selection, design, quotations, and post sale support. Products cost money, consultation is free.
WHICH MIXRITE SERIES IS RIGHT FOR ME?
Series 1 (1 m3/h) High Flow Rate
- Water pressuer: 2.9 to 120 PSI (0.2 to 8 bar)
- Flow rate: 529 to 2645 GPH (20 to 10,000 LPH)
- Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
- Connection: 3/4-Inch
Series 2.5 (2.5 m3/h) Low Flow Rate
- Water pressuer: 2.9 to 120 PSI (0.2 to 8 bar)
- Flow rate: 185 to 660 GPH (7 to 2500 LPH)
- Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
- Connection: 3/4-Inch
Series 3.5 (3.5 m3/h) Low Flow Rate
- Water pressuer: 2.9 to 120 PSI (0.2 to 8 bar)
- Flow rate: 265 to 930 GPH (10 to 3500 LPH)
- Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
- Connection: 3/4-Inch
Series TF-5 (5 m3/h) Low Flow Rate
- Water pressuer: 14.7 to 120 PSI (1 to 8 bar)
- Flow rate: 0.2 to 22 GPH (0.05 to 5 m3/h)
- Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
- Connection: 1-Inch (32 mm)
Series TF-10 (10 m3/h) Low Flow Rate
- Water pressuer: 14.7 to 120 PSI (1 to 8 bar)
- Flow rate: 0.2 to 45 GPH (0.05 to 10 m3/h)
- Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
- Connection: 1-1/2-Inch (50 mm)
Series TF-25 (25 m3/h) Low Flow Rate
- Water pressuer: 14.7 to 120 PSI (1 to 8 bar)
- Flow rate: 9 to 110 GPH (0.2 to 25 m3/h)
- Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
- Connection: 2-Inch (63 mm)
COMMON MIXRITE DOSING PUMPS
|
Model No. |
Flow Rate |
Induction Rates |
Induction % |
Oz/Gal |
mL/Gal |
Chemical Shut-Off |
|
569* |
.5 – 11 GPM (3.4 – 41.6 LPM) |
1000:1 to 111:1 |
.1% to .9% |
.128 – 1.15 |
3.84 – 34.5 |
Yes |
|
570* |
.5 – 11 GPM (3.4 – 41.6 LPM) |
333:1 to 50:1 |
.3% to 2% |
.4 – 2.56 |
12 – 76.8 |
No |
|
571* |
.5 – 11 GPM (3.4 – 41.6 LPM) |
333:1 to 50:1 |
.3% to 2% |
.4 – 2.56 |
12 – 76.8 |
Yes |
|
572 |
.5 – 11 GPM (3.4 – 41.6 LPM) |
250:1 to 25:1 |
.4% to 4% |
.5 – 5.12 |
15 – 153.6 |
Yes |
|
573* |
.5 – 11 GPM (3.4 – 41.6 LPM) |
250:1 to 25:1 |
.4% to 4% |
.5 – 5.12 |
15 – 153.6 |
Yes |
|
577IN |
.5 – 11 GPM (3.4 – 41.6 LPM) |
333:1 to 50:1 |
.3% to 2% |
.4 – 2.56 |
12 – 76.8 |
Yes |
|
579IN |
.5 – 11 GPM (3.4 – 41.6 LPM) |
250:1 to 25:1 |
.3% to 4% |
.4 – 5.12 |
15 – 153.6 |
Yes |
|
1400A or M |
.5 – 14 GPM (.5 – 53 LPM) |
200:1 to 500:1 |
.05% to .2% |
.04 – .25 |
1.2 – 7.5 |
M Model |
|
1401A or M |
.5 – 14 GPM (.5 – 53 LPM) |
1000:1 to 111:14 |
.1% to .9% |
.128 – 1.15 |
3.84 – 34.5 |
M Model |
|
1402A or M |
.5 – 14 GPM (.5 – 53 LPM) |
333:1 to 50:1 |
.3% to 2% |
.4 – 2.56 |
12 – 76.8 |
M Model |
|
1405A or M |
.5 – 14 GPM (.5 – 53 LPM) |
100:1 – 20:1 |
.5% to 5% |
.64 – 6.4 |
19.2 – 192 |
M Model |
|
1410A or M |
.5 – 14 GPM (.5 – 53 LPM) |
100:1 – 10:1 |
1% to 10% |
1.28 – 12.8 |
38.4 – 384 |
M Model |
OPERATING PRINCIPLE
- The pilot operating valve samples the pressure level at multiple points, and controls the opening condition of the diaphragm.
- This operation governs the flow rates to generate a stable 1:10 ratio between lines.
CASE STUDY
- Total water flow rate: 67.3 m3/h
- Desired dosage rate: 0.1%
- Additive amount: 67.3 x 0.1% = 0.0673 m3/h
- Relevant configuration: 4’’, 1.5"
- Main line water flow: 67.3 x 0.9 = 60.57 m3/h
- By-Pass water flow: 67.3 x 0.1 = 6.73 m3/h
- Relevant injector: TF10 0.2%-2%
- Dosage setting on injector: 0.0673 / 6.73 = 1%
FEATURES & BENEFITS
- Keeps constant proportional flow rate
- Hydraulic, volumetric, and non-electric
- Dosing proportional to flowrate
- Precision: surface quality optimized with no waste
- Flow rate between main line and sub-main line will remain 10:1 at wide flow rates
- Working pressure up to 8 bar (116 PSI)
- High UV resistance
- High chemical resistance
- Supplied pre - set. No need for calibration
- Excellent dosing repeatability and homogeneity
- Easy to install, operate and maintain, with no electricity risk