Handheld Moisture Sensor Kit w/ HH150 Readout Meter
Currently, there are no documents available for this product.
Currently, there are no specifications available for this product.
Details
SM150 Kit
- Complete kit for coco, soil, and substrate moisture measurement
- ± 3% accuracy
- Easy to use and highly portable
The SM150 Kit is an affordable tool for obtaining reliable moisture measurements with minimal soil disturbance. The cable and connector are watertight – an essential requirement for potentially wet environments.
The kit comprises an SM150T Coco & Soil Moisture Sensor, a dedicated HH150 Moisture Meter, and a carry case. The kit comes with substrate calibrations for perlite, coir, peat, and mineral wool, as well as soils.
The HH150 handheld meter is lightweight and is very easy to use, being a readout-only device (no data recording or PC complications). To make a measurement, just insert the SM150T into the substrate and press the Read button.
Note: The HH150 Moisture Meter does not provide temperature indication from the SM150T Sensor
The new SM150T measures soil moisture and temperature with research-grade accuracy. It offers stable, robust and reliable performance at a great price.
The new SM150T’s advanced patented electronics and tough build produce a highly dependable sensor with exceptional salinity and temperature stability. The SM150T is engineered to withstand long-term burial – the sensor, connectors, and cable are all environmentally protected to IP68. It offers moisture accuracy of ± 3% (after soil specific calibration) and the built-in temperature sensor achieves ± 0.5° C.
The SM150T is a dual purpose probe – it can be used portably for instant moisture readings, or left installed in the soil connected to a data logger, to provide long-term moisture and temperature data.
Probe Specifications |
|
Accuracy | ± 0.03 m3.m-3 (3%) volumetric water content (VWC) |
± 0.5°C (0 to 40°C for temp sensor) | |
Soil moisture measurement range | 0 to 1.0 m3.m-3 (100%) |
but less accurate above 70% VWC | |
Salinity range | 50 to 1000 mS.m-1 |
± 5% vol over 100 to 1000 mS.m-1 and 0-60% VWC | |
Temperature range | Full accuracy over: 0 to 60°C |
Output | 0 to 1.0 V differential |
Corresponding to 0 to ~0.6 m3.m-3 | |
Power requirement | 5-14 V, ~18 mA for 1s |
Minimum 5 V with 100 m cable | |
Environmental | IP68 with Delta-T supplied cables |
Sample volume | ~55 x 70 mm diameter |
Sample volume is weighted towards soil immediately surrounding the rods | |
Dimensions and weight | Overall: 143 x 40 mm diameter |
Rods: 51 mm x 2.5 mm diameter | |
Weight: 0.1 kg (exc. cable) | |
Sensor calibrations | Individual sensors are interchangeable |
Recalibration advised every 3 years (depending on use) | |
Soil calibrations | Generalized Mineral and Organic soil calibrations are supplied |